| Data Acquisition | Analog Data Acquisition | Three-phase voltage / current / active power / reactive power / frequency acquisition | ✅ | Supports standard Modbus protocol and DIO data acquisition |
| Analog Data Acquisition | Cell voltage / temperature / SOC / SOH acquisition | ✅ | Supports rack-level and PACK-level data acquisition |
| Digital Status Acquisition | Switch status, contactor status, and alarm signal acquisition | ✅ | Supports standard digital input signals |
| Energy Metering | Cumulative charge/discharge energy and peak/flat/valley energy statistics | ✅ | Supports energy meter integration |
| Device Control | Basic Control | Energy storage system start/stop and charge/discharge mode switching | ✅ | Basic modes such as constant power charging/discharging |
| Power Regulation | Active/reactive power command control | ✅ | Supports continuous adjustment from 0% to 100% |
| Grid-connected / Off-grid Switching | Grid-connected / off-grid mode switching control | ⚙️ | Requires PCS support |
| Multi-device Parallel Operation | Multi-cabinet cluster power distribution and current sharing control | ✅ | Dedicated function for station-level control |
| Operation Strategies | Basic Strategies | Scheduled charge/discharge and SOC maintenance | ✅ | Built-in standard function |
| Peak-Valley Arbitrage | Automatic charge/discharge based on time-of-use electricity tariffs | ✅ | Built-in standard function |
| Demand Management | Maximum demand limitation and peak shaving | ✅ | Built-in standard function |
| Reverse Power Protection | PV energy utilization and self-consumption optimization | ✅ | Built-in standard function |
| Protection and Alarms | Level 1 Protection | Overvoltage / undervoltage / overcurrent / overtemperature alarms and shutdown | ✅ | Fault shutdown and alarm reporting |
| Level 2 Protection | Insulation detection, liquid leakage detection, and smoke concentration detection | ⚙️ | Requires connection of corresponding sensors |
| Fault Records | Fault alarm storage, operation data, and SOE event records | ✅ | Local storage capacity ≥10,000 records |
| Communication Protocols | Southbound Communication | Modbus RTU/TCP | ✅ | Built-in standard function |
| Southbound Communication | IEC 61850 MMS | ❌ | Requires ICD model import and configuration |
| Northbound Communication | IEC 103 / IEC 104 Protocol | ❌ | Requires protocol stack migration |
| Human-Machine Interaction | Local Monitoring | Local parameter configuration and status monitoring | ✅ | Standard Web interface included |
| Remote Monitoring | Cloud platform data integration (UniEnergy) | ✅ | Standard MQTT interface |
| Log and Maintenance | Parameter Management | Parameter read/write and setting group switching | ✅ | Built-in standard function |
| Upgrade and Maintenance | Remote firmware upgrade and log export | ✅ | Built-in standard function |